The muscle man among the hot-air blowers leaves no doubts about its performance. It is compactly built and easy to integrate into industrial processes. Just as Leister’s smaller hot-air blowers, VULCAN SYSTEM can be controlled remotely through a standard analog interface.
VULCAN SYSTEM 10 kW
The powerhouse of the hot-air blowers. Its performance speaks for itself.
Technical Data
VULCAN SYSTEM – 3 × 230 V / 10 kW
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 230 |
Power | W | 10000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlet temperature | °C | 650 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Noise emission level | dB(A) | 65 |
Size (L × B × H) | mm | 410 × 276 × 231 |
Weight | kg | 9.3 |
Conformity mark | ||
Approval mark | ||
Protection class I |
VULCAN SYSTEM – 3 × 400 V / 11 kW
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 400 |
Power | W | 11000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlet temperature | °C | 650 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Noise emission level | dB(A) | 65 |
Size (L × B × H) | mm | 410 × 276 × 231 |
Weight | kg | 9.3 |
Conformity mark | ||
Approval mark | ||
Protection class I |
VULCAN SYSTEM – 3 × 480 V / 11 kW
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 480 |
Power | W | 11000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlet temperature | °C | 650 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Noise emission level | dB(A) | 65 |
Size (L × B × H) | mm | 410 × 276 × 231 |
Weight | kg | 9.3 |
Conformity mark | ||
Approval mark | ||
Protection class I |
Downloads
General Catalogs :
GC – General Catalog Process Heat (7,95 MB)
Brochures :
BR – Hot-air blowers (1,28 MB)
BR – Process Heat – useful formulas (0,05 MB)
Manuals :
BA – VULCAN SYSTEM – DE EN IT FR ES PT SV TR CS ZH JA (8,07 MB)
สินค้าที่เกี่ยวข้อง
High performance. Detection of heating element and device overheating with alarm output.
For high-quality clean room production like food & beverage, medical, pharmaceutical, cosmetics and electronics manufacturing.
Only 67 mm wide. Detection of heating element and device overheating with alarm output.
Energy savings effect thanks to hot air recirculation. Maximum air inlet temperature 350 °C / 662°F.
Wide array of applications. Remote control interface for Leister CSS or SPS temperature controller.
Energy savings effect thanks to hot air recirculation. Maximum air inlet temperature of 150°C / 302°F.
High performance. Detection of heating element and device overheating with alarm output.